Altiplano Híbrido

Needs attention

Murcia · Wind + solar + storage · 74 MW installed · 8 technicians · manager Eleonore Hamill

Output now

10.5 MW

Load factor

14 %

Energy today

183 MWh

Availability

97.1 %

Producing

21 / 29

Open alarms

11

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

8.1 m/s WSW

Irradiance

0 W/m²

Temperature

15.5 °C

Cloud cover

29 %

Conditions

Sunny intervals

Substation

Yecla SE 220 kV

Voltage

219.6 kV

Frequency

49.962 Hz

Power factor

0.983

Curtailment

7 %

Day-ahead price

80.71 €/MWh

Assets

29 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Siemens Gamesa SG 6.6-170 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

10.9 MWh

Wind

6.9 m/s

Wind turbine

WTG-02

Nordex N163/5.X · 4.2 MW

Producing
28%

Output

1.16 MW

Today

13.3 MWh

Wind

8.5 m/s

Wind turbine

WTG-03

Siemens Gamesa SG 6.6-170 · 4.2 MW

Producing
9%

Output

0.37 MW

Today

11.6 MWh

Wind

6.6 m/s

Wind turbine

WTG-04

Vestas V150-4.2 · 6.2 MW

Maintenance
0%

Output

0.00 MW

Today

13.6 MWh

Wind

8.4 m/s

Wind turbine

WTG-05

Vestas V150-4.2 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

10.9 MWh

Wind

8.6 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
44%

Output

2.18 MW

Today

17.0 MWh

Wind

9.5 m/s

Tracker block

PV-01

Nextracker NX Horizon · 2.4 MWp

Producing
0%

Output

0.00 MW

Today

6.0 MWh

Availability

96.3 %

Tracker block

PV-02

Soltec SF7 · 2.4 MWp

Producing
0%

Output

0.00 MW

Today

6.5 MWh

Availability

99.2 %

Tracker block

PV-03

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
0%

Output

0.00 MW

Today

5.9 MWh

Availability

93.3 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
0%

Output

0.00 MW

Today

10.8 MWh

Availability

97.5 %

Tracker block

PV-05

Soltec SF7 · 2.4 MWp

Producing
0%

Output

0.00 MW

Today

5.4 MWh

Availability

93.0 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Producing
0%

Output

0.00 MW

Today

10.3 MWh

Availability

95.5 %

Tracker block

PV-07

Soltec SF7 · 2.4 MWp

Producing
0%

Output

0.00 MW

Today

6.3 MWh

Availability

99.5 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Maintenance
0%

Output

0.00 MW

Today

5.3 MWh

Availability

95.8 %

Tracker block

PV-09

Nextracker NX Horizon · 3.2 MWp

Producing
0%

Output

0.00 MW

Today

7.7 MWh

Availability

99.7 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
0%

Output

0.00 MW

Today

10.2 MWh

Availability

94.5 %

Tracker block

PV-11

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
0%

Output

0.00 MW

Today

8.7 MWh

Availability

98.7 %

Tracker block

PV-12

Soltec SF7 · 3.2 MWp

Curtailed
0%

Output

0.00 MW

Today

4.2 MWh

Availability

98.7 %

Tracker block

PV-13

Soltec SF7 · 4.0 MWp

Fault
0%

Output

0.00 MW

Today

8.8 MWh

Availability

96.8 %

Tracker block

PV-14

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
0%

Output

0.00 MW

Today

9.4 MWh

Availability

97.3 %

Inverter skid

INV-01

Sungrow SG3125HV-MV · 4.6 MVA

Maintenance
0%

Output

0.00 MW

Today

10.1 MWh

Availability

96.9 %

Inverter skid

INV-02

Sungrow SG3125HV-MV · 3.1 MVA

Producing
10%

Output

0.31 MW

Today

9.1 MWh

Availability

96.6 %

Inverter skid

INV-03

Huawei SUN2000-215KTL · 5.0 MVA

Producing
8%

Output

0.38 MW

Today

14.5 MWh

Availability

99.4 %

Inverter skid

INV-04

Huawei SUN2000-215KTL · 3.1 MVA

Curtailed
5%

Output

0.15 MW

Today

5.1 MWh

Availability

95.4 %

Inverter skid

INV-05

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
4%

Output

0.20 MW

Today

12.0 MWh

Availability

98.5 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
3%

Output

0.14 MW

Today

10.2 MWh

Availability

99.5 %

Inverter skid

INV-07

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
3%

Output

0.15 MW

Today

10.4 MWh

Availability

98.7 %

Battery container

BESS-01

CATL EnerOne+ · 5.0 MW

Producing
76%

Output

-3.80 MW

Today

0.7 MWh

State of charge

91 %

Battery container

BESS-02

CATL EnerOne+ · 3.9 MW

Producing
77%

Output

-3.00 MW

Today

0.5 MWh

State of charge

91 %

Alarms
Site alarms
Most recent events from this site's assets.

Blade ice detected

WTG-05· 10-28 14:59
Low

Row stowed – high wind

PV-05· 10-28 14:53
Low

IGBT temperature high

INV-01· 10-28 14:34
Low

Blade ice detected

WTG-04· 10-28 10:56
Medium

Module temperature above limit

PV-13· 10-28 10:36
Medium

Soiling loss above threshold

PV-08· 10-28 06:32
Medium

Communication lost to controller

PV-13· 10-28 05:47
High

Power limited by temperature

INV-03· 10-28 02:02
Medium