Altiplano Híbrido

Needs attention

Murcia · Wind + solar + storage · 74 MW installed · 8 technicians · manager Eleonore Hamill

Output now

8.1 MW

Load factor

11 %

Energy today

189 MWh

Availability

97.1 %

Producing

21 / 29

Open alarms

11

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

8.5 m/s SSW

Irradiance

0 W/m²

Temperature

13.6 °C

Cloud cover

16 %

Conditions

Sunny intervals

Substation

Yecla SE 220 kV

Voltage

220.6 kV

Frequency

50.015 Hz

Power factor

0.984

Curtailment

7 %

Day-ahead price

58.67 €/MWh

Assets

29 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Siemens Gamesa SG 6.6-170 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

11.6 MWh

Wind

5.3 m/s

Wind turbine

WTG-02

Nordex N163/5.X · 4.2 MW

Producing
36%

Output

1.51 MW

Today

14.6 MWh

Wind

9.1 m/s

Wind turbine

WTG-03

Siemens Gamesa SG 6.6-170 · 4.2 MW

Producing
3%

Output

0.11 MW

Today

12.9 MWh

Wind

5.3 m/s

Wind turbine

WTG-04

Vestas V150-4.2 · 6.2 MW

Maintenance
0%

Output

0.00 MW

Today

14.3 MWh

Wind

5.8 m/s

Wind turbine

WTG-05

Vestas V150-4.2 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

11.6 MWh

Wind

7.1 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
3%

Output

0.16 MW

Today

18.0 MWh

Wind

5.4 m/s

Tracker block

PV-01

Nextracker NX Horizon · 2.4 MWp

Producing
0%

Output

0.00 MW

Today

6.0 MWh

Availability

96.3 %

Tracker block

PV-02

Soltec SF7 · 2.4 MWp

Producing
0%

Output

0.00 MW

Today

6.5 MWh

Availability

99.2 %

Tracker block

PV-03

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
0%

Output

0.00 MW

Today

5.9 MWh

Availability

93.3 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
0%

Output

0.00 MW

Today

10.8 MWh

Availability

97.5 %

Tracker block

PV-05

Soltec SF7 · 2.4 MWp

Producing
0%

Output

0.00 MW

Today

5.4 MWh

Availability

93.0 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Producing
0%

Output

0.00 MW

Today

10.3 MWh

Availability

95.5 %

Tracker block

PV-07

Soltec SF7 · 2.4 MWp

Producing
0%

Output

0.00 MW

Today

6.3 MWh

Availability

99.5 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Maintenance
0%

Output

0.00 MW

Today

5.5 MWh

Availability

95.8 %

Tracker block

PV-09

Nextracker NX Horizon · 3.2 MWp

Producing
0%

Output

0.00 MW

Today

7.7 MWh

Availability

99.7 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
0%

Output

0.00 MW

Today

10.2 MWh

Availability

94.5 %

Tracker block

PV-11

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
0%

Output

0.00 MW

Today

8.7 MWh

Availability

98.7 %

Tracker block

PV-12

Soltec SF7 · 3.2 MWp

Curtailed
0%

Output

0.00 MW

Today

4.2 MWh

Availability

98.7 %

Tracker block

PV-13

Soltec SF7 · 4.0 MWp

Fault
0%

Output

0.00 MW

Today

9.2 MWh

Availability

96.8 %

Tracker block

PV-14

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
0%

Output

0.00 MW

Today

9.4 MWh

Availability

97.3 %

Inverter skid

INV-01

Sungrow SG3125HV-MV · 4.6 MVA

Maintenance
0%

Output

0.00 MW

Today

10.6 MWh

Availability

96.9 %

Inverter skid

INV-02

Sungrow SG3125HV-MV · 3.1 MVA

Producing
0%

Output

0.00 MW

Today

9.3 MWh

Availability

96.6 %

Inverter skid

INV-03

Huawei SUN2000-215KTL · 5.0 MVA

Producing
11%

Output

0.57 MW

Today

14.7 MWh

Availability

99.4 %

Inverter skid

INV-04

Huawei SUN2000-215KTL · 3.1 MVA

Curtailed
2%

Output

0.05 MW

Today

5.3 MWh

Availability

95.4 %

Inverter skid

INV-05

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
12%

Output

0.55 MW

Today

12.2 MWh

Availability

98.5 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
14%

Output

0.66 MW

Today

10.7 MWh

Availability

99.5 %

Inverter skid

INV-07

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
4%

Output

0.19 MW

Today

10.9 MWh

Availability

98.7 %

Battery container

BESS-01

CATL EnerOne+ · 5.0 MW

Producing
70%

Output

-3.50 MW

Today

3.8 MWh

State of charge

74 %

Battery container

BESS-02

CATL EnerOne+ · 3.9 MW

Producing
71%

Output

-2.77 MW

Today

3.0 MWh

State of charge

74 %

Alarms
Site alarms
Most recent events from this site's assets.

Blade ice detected

WTG-05· 10-28 15:47
Low

Row stowed – high wind

PV-05· 10-28 15:41
Low

IGBT temperature high

INV-01· 10-28 15:22
Low

Blade ice detected

WTG-04· 10-28 11:45
Medium

Module temperature above limit

PV-13· 10-28 11:24
Medium

Soiling loss above threshold

PV-08· 10-28 07:20
Medium

Communication lost to controller

PV-13· 10-28 06:35
High

Power limited by temperature

INV-03· 10-28 02:51
Medium